Zephyr AK7548ASX Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Exaustores Zephyr AK7548ASX. Zephyr AK7548ASX Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Use, Care, and Installation Guide
www.zephyronline.com
Model number:
Serial Number:
Date of Purchase:
Sales Dealer:
AUG08.0101 © Zephyr Corporation
Cypress Outdoor Hood
AK7836ASX
AK7842ASX
AK7848ASX
READ AND SAVE THESE INSTRUCTIONS
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Cypress Outdoor Hood

Use, Care, and Installation Guidewww.zephyronline.comModel number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr CorporationCypre

Página 2

8www.zephyronline.comInstallation – Specifi cations35 15/16” (36”)41 15/16” (42”)47 15/16” (48”)12”*10 ”27”4”18”1 1/8”8 9/16”13 3/16”2 5/16”6 7/16”2

Página 3 - Table of Contents

9ELECTRICALWARNINGAll Electrical work must by performed by qualifi ed electrician or person with similar technical know how and background.For personal

Página 4 - Important Safety Notice

10www.zephyronline.comC/LC/LAB12 3/8”min30”4”wood boardfig. 2fig. 1Installation – Mounting the Range Hood1. Measure distance from range top to hood

Página 5

11CBI-600B AND PBI-1100A BLOWER INSTALLATION1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2)

Página 6 - List of Materials

12www.zephyronline.comInstallation – Remote Blower Preparation1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10”

Página 7 - Total ductwork =

13 Light On/OffBy pressing , the light is switched On and Off. is on, is off. Blower Speed SelectionThe 2 speed levels are selecte

Página 8 - Min 30" - Max 36"

14www.zephyronline.comSURFACE MAINTENANCE:Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent,

Página 9 - WARNING FIRE HAZARD

15REPLACING LIGHT BULBSCAUTION: Light bulb becomes extremely hot when turned on.DO NOT touch bulb until switched off and cooled. Touching hot bulbs co

Página 10 - Installation – Specifi cations

Troubleshooting16www.zephyronline.comTROUBLESHOOTING PROCEDURES FOR CYPRESSIssue Cause What to doAfter installation, the unit doesn’t work.1. The pow

Página 11 - Installation – Electrical

17DESCRIPTION PART # Replacement PartsLight Bulb MR16 (GU10) 35W (each) Z0B-0023Baffl e Filter (each) 50210009Option

Página 12

www.zephyronline.com

Página 13

1-888-880-8368STAPLE YOUR RECEIPT HERETO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (refe

Página 14

1SAFETY NOTICE ... 2-3LIST OF MATERIALS ...

Página 15 - Blower Speed Selection

Important Safety NoticeREAD AND SAVE THESE INSTRUCTIONS2www.zephyronline.comWARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN

Página 16 - SURFACE MAINTENANCE:

Important Safety Notice3WARNINGTO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.CAUTIONTo reduce risk of fi re and to properly exhaust air outside -

Página 17 - Maintenance – Lights

List of Materials4www.zephyronline.comMODELS: AK7836ASX, AK7842ASX, AK7848ASXPARTS SUPPLIED1 - Hood3 - Baffl e fi lters (4 for AK7848ASX)2 - Halogen lig

Página 18 - Troubleshooting

5Installation – Ducting Calculation SheetDuct piecesTo t a lEquivalent numberlength x used =3-1/ 4” x 10”Rect.,straight1 Ft. x ( ) =

Página 19 - List of Parts and Accessories

Installation – Mounting Height & Clearance6www.zephyronline.comDUCTINGA minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maint

Página 20 - Limited Warranty

7WARNING FIRE HAZARDNEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be